Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9008914

- Product Categories
- Friendly Links
Information Name: | Supply Xinjiang Karamay fire water tank UV sterilizer |
Published: | 2013-06-13 |
Validity: | 999 |
Specifications: | UV-LZC |
Quantity: | 1000.00 |
Price Description: | |
Detailed Product Description: | Karamay ultraviolet sterilizer manufacturers Karamay benefits of environmental protection equipment Co., Ltd. Zhao Xiang 13231166569/0311-89943986/qq1838722340: UV sterilizer Karamay, Xinjiang Karamay classification and structure and components of UV disinfection of drinking water disinfection by ultraviolet Karamay Flow Regimes gravity into the open Karamay ultraviolet disinfection of drinking water and a closed pressurized UV disinfection of drinking water Karamay. Currently used in enclosed UV disinfection of drinking water Karamay majority. Enclosed UV disinfection of drinking water appliances Karamay the disinfection lamp with a metal cylinder and the disinfected water enclosed. Enclosed Karamay ultraviolet disinfection of drinking water cylinder made of stainless steel, closed drinking water UV disinfection Karamay do its wall polished to enhance the ability to UV reflection to enhance the cylinder body ultraviolet radiation intensity. Enclosed Karamay UV disinfection of drinking water in the barrel can be fitted with baffles to change the operating status of the water to avoid water dead. Enclosed Karamay ultraviolet disinfection of drinking water must have inlet, outlet and drain pipes, inlet flow rate can be set on the indicating instrument, in order to simplify closed Karamay UV disinfection of drinking water structure, you can also drain pipe and a flow meter installed in the sterilizer connected pipeline. Enclosed UV disinfection of drinking water Karamay prominently instructions should have lit the lamp, lit timing instructions or UV intensity indicating instrument. Karamay ultraviolet disinfection of drinking water is a core component UV lamp, the role is to convert electrical energy into light energy ultraviolet light. Karamay ultraviolet disinfection of drinking water inside the tube is filled with inert gas and mercury vapor, low-pressure mercury UV lamp shell vapor pressure of 0.8Pa. Karamay single lamp UV disinfection of drinking water features a lamp, the lamp is located in the center of the cylinder section. Multi-lamp UV disinfection of drinking water in Karamay lamp layout principles, is to make drinking water UV disinfection Karamay various points within the cylinder sections have substantially the same intensity of ultraviolet radiation. Straight-tube low-pressure mercury quartz UV light disinfection implementation of national industry standards YY/T0 160-94. UV disinfection of drinking water Karamay lamp quartz tube, transparent purple rate of not less than 92%, the working pressure 1.0MPa, test pressure 1.2MPa. In order to improve drinking water UV disinfection equipment Karamay the total amount of water, you can use multiple UV disinfection of drinking water Karamay monocular body in series and parallel combinations. Practice has proved that the same radiation dose lighting, two kinds of combinations of sanitizing effect no significant difference. UV disinfection of drinking water Karamay series product specifications at rated flow rate should reach sterilizing radiation dose necessary. 2 UV disinfection of drinking water Karamay main technical characteristics 2.1 Xinjiang Karamay ultraviolet disinfection of drinking water influent and effluent quality drinking water UV disinfection Karamay influent and effluent quality should meet the GB 3838-88 surface water quality requirements, applicable in centralized drinking water source protection areas of water bodies, total coliform value should be less than 10 000 / L. For surface water, drinking water during Karamay UV disinfection disinfection of drinking water as before, generally after coagulation, sedimentation, filtration and other treatment. GB5749-85 "drinking water health standards" requirement Karamay after UV disinfection of drinking water purification for drinking water sources that the total coliform value should not be greater than 1 000 / L. Karamay drinking water UV disinfection of treated surface water is purified, city buildings tank or a secondary water supply, can be used as sources of drinking water supplied directly to the water, the water quality should meet the drinking water health standards of the relevant provisions. Karamay drinking water UV disinfection bacteriological indicators that can take total coliforms less than 1 000 / L, total bacterial count of less than 2 000 / mL, chroma less than 15 degrees, the total iron content of less than 0.3mg / L, turbidity of less than 5 degrees. 2.2 UV disinfection of drinking water Karamay working conditions ambient temperature, UV disinfection of drinking water Karamay radiation intensity UV light, thus affecting disinfection disinfection. Temperature 5 ℃ ~ 40 ℃ range of drinking water disinfection, UV disinfection Karamay effect changes with decreasing temperature, UV light output will be reduced below 5 ℃ even cause difficulty in starting the lamp. UV disinfection of drinking water in Karamay, lamp set in a quartz tube, and its role in addition to prevent drinking water UV disinfection lamps Karamay ruptured water pollution, there are also reduced because the water temperature is too low impact on the efficiency of the UV lamp function. Therefore, the drinking water UV disinfection Karamay water temperature and ambient temperature is above 5 ℃. UV disinfection of drinking water Karamay working environment relative humidity should be less than 65%, the maximum not more than 90%. High relative humidity, severe deterioration of the electrical components of the operating conditions, and the air, the small droplets increases, block UV intensity of the radiation decreases. Of the grid frequency is 50Hz. When the supply voltage changes, ultraviolet disinfection of drinking water Karamay radiation intensity UV lamp voltage increases and enhanced UV disinfection of drinking water Karamay capacity increased. Karamay ultraviolet disinfection of drinking water supply voltage should be stabilized at 220V ± 10% range, in which the supply voltage fluctuation range, the sterilizer disinfection capacity will be between 15% to 20% of the variation. 2.3 Karamay UV disinfection of drinking water disinfection capability disinfectant Karamay UV disinfection of drinking water disinfection capability refers to the case in the nominal amount of water to kill microorganisms in water features. Karamay UV disinfection of drinking water disinfection capacity of its physical expression represents the state of the irradiation dose: radiation dose = radiation intensity X sterilizer effective water volume (L) / sterilizer rated into the water × 3.6 OK UV disinfection of drinking water disinfection Karamay capacity core issue is how to determine the radiation dose. Killing microbes require different type of irradiation dose, and the microorganism is present in a wide variety of water. Selected ultraviolet disinfection of drinking water in Xinjiang Karamay irradiation dose is too high will waste unnecessary energy, too low and reach the purpose of disinfection. Disinfection of water via the water should be focused on killing bacterial disease, generally considered Kelamayi UV disinfection of drinking water can be provided not less than the minimum irradiation dose 9 000μW / (cm2 · s), factory should be greater than 12 000μW / (cm2 · s). Karamay in the drinking water UV sterilizer, UV radiation intensity of each point is different. UV lamp emitted through the quartz tube cause some attenuation of the intensity passing through the water layer with the water depth increases. UV disinfection of drinking water in Karamay how only the case of lamps, ultraviolet radiation within the cylinder cross-section intensity distribution is more complex calculations to ensure that each point strength is broadly consistent with the structural design of the primary problem. UV disinfection of drinking water Karamay effective use of the process, increasing the radiation dose is reduced over time, mainly because of UV disinfection of drinking water Karamay lamp radiation intensity changes, ultraviolet disinfection of drinking water tube Karamay the body surface and the quartz sleeve fouling caused by ultraviolet reflectivity and transparency purple is also an important reason for lower. UV disinfection of drinking water Karamay effective usage time of the lamp is its radiation intensity from the factory standard value dropped by 30% cumulative time, drinking water UV disinfection lamp Karamay useful life should be up to 13000h. UV disinfection of drinking water Karamay specified by the manufacturer in proximity useful life, should strengthen the monitoring of water quality, timely replacement of failed lamps. In actual operation, where necessary, the use of the standard value of the lamp failure, appropriate reduction of UV disinfection of drinking water Karamay into the water to ensure the necessary radiation dose, you can still obtain satisfactory water quality. 2.4 microorganisms by ultraviolet light irradiation resurrection in Karamay UV disinfection of drinking water, a variety of different microorganisms are as ultraviolet radiation damage and even death. However, all of any biological ability to repair damage to a certain microbial no exception. Microbial UV damage can be reversed by visible light is called resurrection, effective 330nm ~ 480nm wavelength range includes the visible and near UV. Repair of microbial species and due to hit by ultraviolet extent varies. Some lack the enzyme microorganism matt light resurrection resurrection capability. UV fluence increases, photoreactivation rate decreased when the dose reaches 60 000μW/cm2, the E. coli photoreactivation disappear. Photoreactivation mechanisms are: the action of the enzyme photoreactivation, connected together can be reversed photoproduct formation of thymine dimers and monomers depolymerization, the DNA to restore normal function and structure of the DNA replication at the site of injury ignored and bypassed to achieve cutting repair and recombination repair. In order to avoid the phenomenon of photoreactivation, UV disinfection of drinking water Karamay should guarantee a certain dose of ultraviolet irradiation, sterilization should be installed in the tank outlet pipe, after disinfection of the water-box, to avoid prolonged contact with the light. 3 UV sterilizer Karamay Karamay Monitoring System 3.1 UV sterilizer lamp UV radiation intensity Karamay ultraviolet radiation intensity ultraviolet disinfection with ultraviolet radiation intensity was determined by measuring, the instrument shall be approved by the national legal units calibrated and the calibration validity period. When the lamp should be measured at the horizontal position, the instrument receiving the probe in the middle of the lamp surface normals at 1m. Ambient temperature of 25 ℃ ± 3%, relative humidity not exceeding 65%, the stability of the discharge tube before measurement time is not less than 10min, electrical measuring instrument accuracy is not less than 0.5, ballasts comply with GB2313 requirements, supply voltage 220V ± 2%, 50Hz. 3.2 Xinjiang Karamay UV sterilizer sterilizer sterilizer irradiance irradiance measured using the same instrumentation and measurement conditions 4.1. Instrument sterilizer test probe is placed holes, the distance from the surface is less than 5cm. The measured radiation intensity and the nominal flow of water residence time in the sterilizer is the radiation dose of the product. 3.3 Xinjiang Karamay ultraviolet sterilizer for water disinfection monitoring of natural water disinfection should meet the requirements. Sterilizer lamp fully open. In the case of nominal water disinfection, but also water quality should meet the total bacterial count is less than 100 / mL, total coliform count is less than 3 / L. Water testing shall conform to "drinking water standards test" (GB5750). 3.4 Xinjiang Karamay artificial ultraviolet disinfection disinfection detect contamination indicator bacteria using Escherichia coli 8099. Will be viable count of bacteria, with dechlorinated tap water dubbed 1 000cfu / L of water contamination do disinfection test, the number of total coliforms in water is less than 3 / L. 4 Karamay UV sterilizer sterilizer operation and management of the operation and management is not complicated. Usually should be noted whether all sterilizer lamp lit, the power supply voltage is normal, the inlet and outlet is unobstructed. Regular water quality monitoring, the tube should be increased monitoring frequency near the end validity, timeliness replace the lamp failure. Every three months on the quartz glass tube, the tube, the tube wall sterilizer cleaned once, first scrub with gauze dipped in alcohol, and then wipe with a soft cloth, clean and working gloves should be worn to prevent hand oil contamination, affecting ultraviolet transmittance and reflectivity. This information from the ultraviolet disinfection Karamay Karamay Zeppelin Environmental Protection Equipment Co., Ltd. self-publish, there are business please contact Environmental Protection Equipment Co., Ltd., Xinjiang Karamay Zeppelin. ? |
Admin>>>
You are the 14451 visitor
Copyright © GuangDong ICP No. 10089450, The stone house Zhuang Xinzhuo Environmental Protection Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 14451 visitor
Copyright © GuangDong ICP No. 10089450, The stone house Zhuang Xinzhuo Environmental Protection Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility